web-dev-qa-db-ja.com

smartctlは全体的なヘルステストをパスしたと報告しますが、テストは失敗しましたか?

なぜSMART overall-health self-assessment test result: PASSED 2つのテストが失敗したときに表示されますか?

Sudo smartctl -a /dev/sdc 
smartctl 6.6 2018-12-05 r4851 [x86_64-linux-4.14.98] (local build)
Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family:     Western Digital AV-GP (AF)
Device Model:     WDC WD20EURS-63SPKY0
Serial Number:    WD-WMC1T2763021
LU WWN Device Id: 5 0014ee 6addb4b7c
Firmware Version: 80.00A80
User Capacity:    2,000,398,934,016 bytes [2.00 TB]
Sector Sizes:     512 bytes logical, 4096 bytes physical
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ACS-2 (minor revision not indicated)
SATA Version is:  SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s)
Local Time is:    Sun Feb 24 13:43:30 2019 GMT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                    was never started.
                    Auto Offline Data Collection: Disabled.
Self-test execution status:      ( 117) The previous self-test completed having
                    the read element of the test failed.
Total time to complete Offline 
data collection:        (27240) seconds.
Offline data collection
capabilities:            (0x7b) SMART execute Offline immediate.
                    Auto Offline data collection on/off support.
                    Suspend Offline collection upon new
                    command.
                    Offline surface scan supported.
                    Self-test supported.
                    Conveyance Self-test supported.
                    Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                    power-saving mode.
                    Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                    General Purpose Logging supported.
Short self-test routine 
recommended polling time:    (   2) minutes.
Extended self-test routine
recommended polling time:    ( 275) minutes.
Conveyance self-test routine
recommended polling time:    (   5) minutes.
SCT capabilities:          (0x70b5) SCT Status supported.
                    SCT Feature Control supported.
                    SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x002f   200   200   051    Pre-fail  Always       -       0
  3 Spin_Up_Time            0x0027   180   179   021    Pre-fail  Always       -       5991
  4 Start_Stop_Count        0x0032   100   100   000    Old_age   Always       -       113
  5 Reallocated_Sector_Ct   0x0033   200   200   140    Pre-fail  Always       -       0
  7 Seek_Error_Rate         0x002e   200   200   000    Old_age   Always       -       0
  9 Power_On_Hours          0x0032   092   092   000    Old_age   Always       -       6354
 10 Spin_Retry_Count        0x0032   100   100   000    Old_age   Always       -       0
 11 Calibration_Retry_Count 0x0032   100   253   000    Old_age   Always       -       0
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       -       56
192 Power-Off_Retract_Count 0x0032   200   200   000    Old_age   Always       -       46
193 Load_Cycle_Count        0x0032   200   200   000    Old_age   Always       -       66
194 Temperature_Celsius     0x0022   122   114   000    Old_age   Always       -       28
196 Reallocated_Event_Count 0x0032   200   200   000    Old_age   Always       -       0
197 Current_Pending_Sector  0x0032   200   200   000    Old_age   Always       -       0
198 Offline_Uncorrectable   0x0030   100   253   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x0032   200   200   000    Old_age   Always       -       0
200 Multi_Zone_Error_Rate   0x0008   200   200   000    Old_age   Offline      -       1

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Short offline       Completed: read failure       50%      6354         4377408
# 2  Extended offline    Completed: read failure       90%      6354         4377408

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
2

あなたのSMART属性はすべて良好な状態であり、No Errors Logged

お読みください: ATAドライブはセルフテストに失敗していますが、SMARTヘルスステータスは「合格」です。何が起こっているのですか?

ドライブがセルフテストに失敗しても「PASSED」のままである場合SMARTヘルスステータスの場合、これは通常、ディスクに破損した(訂正不可能な= UNC)セクターがあることを意味します。これは、そのセクターに保存されているECCデータがそのセクターに保存されているユーザーデータと一致せず、セクターを読み取ろうとするとUNCエラーで失敗します。これは一時的な一時的な影響である可能性があります。ディスクの書き込み中に突然電源が切断されましたセクターにECCコードまたはデータが破損していますが、セクターcouldは新しいデータを正しく保存しています。または、永久的な影響である可能性があります。ほこりのほこりによって磁気メディアが損傷し、セクターが新しいデータを正しく保存していません。

ディスクがデータのセクターを1回読み取ることができ、損傷が一時的ではなく永続的である場合、ディスクファームウェアはセクターを「不良」としてマークし、スペアセクターを割り当てて置き換えます。しかし、ディスクがセクターを一度も読み取ることができない場合は、将来のある時点でセクターからデータを読み取ることができることを期待して、セクターを再割り当てしません。 読み取り不可能な(破損した)セクターへの書き込みにより、問題が修正されます。損傷が一時的なものである場合、新しい整合性のあるデータがセクターに書き込まれます。損傷が永続的である場合、書き込みはセクターの再割り当てを強制します。このセクターを強制的に再割り当てする方法についての説明は Bad block HOWTO を参照してください(Linuxのみ)。

ファームウェアがサーボの故障など、他の問題の兆候を検出していないため、ディスクはまだ正常性ステータスを通過しています。

このようなディスクは、多くの場合、ディスクメーカーの「ディスクの評価と修復」ユーティリティを使用して修復できます。注意:これにより、失われたセクターの再割り当てが強制され、ディスク上のファイルシステムが破損または破壊される可能性があります。一般的なLinuxの説明については Bad block HOWTO を参照してください。

ddまたは何らかの「修復ユーティリティ」を使用して、読み取り不可能なセクターを修正することができます。最初にドライブをバックアップしてください!

4
Freddy

smartctlでは、すべてが大丈夫であることを伝える単純なコマンドはありません... smartctl -Hは偽の友達であり、信頼されていません。完全な出力を確認する必要があります。

SMART overall-health self-assessment test result: PASSED

PASSEDと表示されている限り、意味はありません。無視して、とにかく故障したドライブを交換してください。

Offline data collection status: 
    (0x00) Offline data collection activity was never started.
           Auto Offline Data Collection: Disabled.

補足として、Auto Offline Data Collectionsmartdを設定してセルフテストを定期的に実行し、メール通知を送信します。

6354時間ごとに1回セルフテストを実行するのは信頼性が高すぎるため、定期的なテストを行わないと、ハードドライブのエラーが検出されずに、何もすることができなくなります。

3
frostschutz