SamsungRC530ノートブックとOCZVertex-3 6Gbps SATASSDがAHCIモードで動作しています。
# dmesg | grep DMI
SAMSUNG ELECTRONICS CO., LTD. RC530/RC730/RC530/RC730, BIOS 03WD.M008.20110927.PSA 09/27/2011
# lspci -nn
00:1f.2 SATA controller [0106]: Intel Corporation 6 Series/C200 Series Chipset Family 6 port SATA AHCI Controller [8086:1c03] (rev 04)
# sdparm -a /dev/sda
/dev/sda: ATA OCZ-VERTEX3 2.15
起動時に、次のメッセージがdmesg
に表示されます(私はDebian wheezy @ Linux 3.2.8を実行しています)。
# dmesg | grep -iE '(ata|ahci)'
[ 5.179783] ahci 0000:00:1f.2: version 3.0
[ 5.179802] ahci 0000:00:1f.2: PCI INT B -> GSI 19 (level, low) -> IRQ 19
[ 5.179864] ahci 0000:00:1f.2: irq 42 for MSI/MSI-X
[ 5.195424] ahci 0000:00:1f.2: AHCI 0001.0300 32 slots 6 ports 6 Gbps 0x5 impl SATA mode
[ 5.195429] ahci 0000:00:1f.2: flags: 64bit ncq sntf pm led clo pio slum part ems apst
[ 5.195436] ahci 0000:00:1f.2: setting latency timer to 64
[ 5.204035] scsi0 : ahci
[ 5.204301] scsi1 : ahci
[ 5.204447] scsi2 : ahci
[ 5.204592] scsi3 : ahci
[ 5.204682] scsi4 : ahci
[ 5.204799] scsi5 : ahci
[ 5.204917] ata1: SATA max UDMA/133 abar m2048@0xf7c06000 port 0xf7c06100 irq 42
[ 5.204920] ata2: DUMMY
[ 5.204923] ata3: SATA max UDMA/133 abar m2048@0xf7c06000 port 0xf7c06200 irq 42
[ 5.204924] ata4: DUMMY
[ 5.204926] ata5: DUMMY
[ 5.204927] ata6: DUMMY
[ 5.523039] ata3: SATA link up 1.5 Gbps (SStatus 113 SControl 300)
[ 5.525911] ata3.00: ATAPI: TSSTcorp CDDVDW SN-208BB, SC00, max UDMA/100
[ 5.531006] ata1: SATA link up 6.0 Gbps (SStatus 133 SControl 300)
[ 5.533703] ata3.00: configured for UDMA/100
[ 5.542790] ata1.00: ATA-8: OCZ-VERTEX3, 2.15, max UDMA/133
[ 5.542800] ata1.00: 117231408 sectors, multi 16: LBA48 NCQ (depth 31/32), AA
[ 5.552751] ata1.00: configured for UDMA/133
[ 5.553050] scsi 0:0:0:0: Direct-Access ATA OCZ-VERTEX3 2.15 PQ: 0 ANSI: 5
[ 5.559621] scsi 2:0:0:0: CD-ROM TSSTcorp CDDVDW SN-208BB SC00 PQ: 0 ANSI: 5
[ 5.564059] sd 0:0:0:0: [sda] 117231408 512-byte logical blocks: (60.0 GB/55.8 GiB)
[ 5.564127] sd 0:0:0:0: [sda] Write Protect is off
[ 5.564131] sd 0:0:0:0: [sda] Mode Sense: 00 3a 00 00
[ 5.564158] sd 0:0:0:0: [sda] Write cache: enabled, read cache: enabled, doesn't support DPO or FUA
[ 5.564582] sda: sda1
[ 5.564810] sd 0:0:0:0: [sda] Attached SCSI disk
[ 5.572006] sr0: scsi3-mmc drive: 16x/24x writer dvd-ram cd/rw xa/form2 cdda tray
[ 5.572010] cdrom: Uniform CD-ROM driver Revision: 3.20
[ 5.572189] sr 2:0:0:0: Attached scsi CD-ROM sr0
[ 6.717181] ata1.00: exception Emask 0x50 SAct 0x1 SErr 0x280900 action 0x6 frozen
[ 6.717238] ata1.00: irq_stat 0x08000000, interface fatal error
[ 6.717291] ata1: SError: { UnrecovData HostInt 10B8B BadCRC }
[ 6.717342] ata1.00: failed command: READ FPDMA QUEUED
[ 6.717395] ata1.00: cmd 60/50:00:20:39:58/00:00:00:00:00/40 tag 0 ncq 40960 in
[ 6.717396] res 40/00:00:20:39:58/00:00:00:00:00/40 Emask 0x50 (ATA bus error)
[ 6.717503] ata1.00: status: { DRDY }
[ 6.717553] ata1: hard resetting link
[ 7.033417] ata1: SATA link up 6.0 Gbps (SStatus 133 SControl 300)
[ 7.055234] ata1.00: configured for UDMA/133
[ 7.055262] ata1: EH complete
[ 7.147280] ata1.00: exception Emask 0x10 SAct 0xf8 SErr 0x280100 action 0x6 frozen
[ 7.147340] ata1.00: irq_stat 0x08000000, interface fatal error
[ 7.147393] ata1: SError: { UnrecovData 10B8B BadCRC }
[ 7.147460] ata1.00: failed command: READ FPDMA QUEUED
[ 7.147529] ata1.00: cmd 60/08:18:88:17:41/00:00:02:00:00/40 tag 3 ncq 4096 in
[ 7.147531] res 40/00:38:50:99:64/00:00:02:00:00/40 Emask 0x10 (ATA bus error)
[ 7.147691] ata1.00: status: { DRDY }
[ 7.147754] ata1.00: failed command: READ FPDMA QUEUED
[ 7.147821] ata1.00: cmd 60/00:20:f8:42:4c/01:00:02:00:00/40 tag 4 ncq 131072 in
[ 7.147822] res 40/00:38:50:99:64/00:00:02:00:00/40 Emask 0x10 (ATA bus error)
[ 7.147977] ata1.00: status: { DRDY }
[ 7.148036] ata1.00: failed command: READ FPDMA QUEUED
[ 7.148100] ata1.00: cmd 60/50:28:f8:43:4c/00:00:02:00:00/40 tag 5 ncq 40960 in
[ 7.148101] res 40/00:38:50:99:64/00:00:02:00:00/40 Emask 0x10 (ATA bus error)
[ 7.148255] ata1.00: status: { DRDY }
[ 7.148315] ata1.00: failed command: READ FPDMA QUEUED
[ 7.148379] ata1.00: cmd 60/00:30:50:98:64/01:00:02:00:00/40 tag 6 ncq 131072 in
[ 7.148380] res 40/00:38:50:99:64/00:00:02:00:00/40 Emask 0x10 (ATA bus error)
[ 7.148534] ata1.00: status: { DRDY }
[ 7.148593] ata1.00: failed command: READ FPDMA QUEUED
[ 7.148657] ata1.00: cmd 60/00:38:50:99:64/01:00:02:00:00/40 tag 7 ncq 131072 in
[ 7.148658] res 40/00:38:50:99:64/00:00:02:00:00/40 Emask 0x10 (ATA bus error)
[ 7.148813] ata1.00: status: { DRDY }
[ 7.148875] ata1: hard resetting link
[ 7.464842] ata1: SATA link up 6.0 Gbps (SStatus 133 SControl 300)
[ 7.486794] ata1.00: configured for UDMA/133
[ 7.486822] ata1: EH complete
[ 7.546395] ata1.00: exception Emask 0x10 SAct 0x2f SErr 0x280100 action 0x6 frozen
[ 7.546470] ata1.00: irq_stat 0x08000000, interface fatal error
[ 7.546531] ata1: SError: { UnrecovData 10B8B BadCRC }
[ 7.546588] ata1.00: failed command: READ FPDMA QUEUED
[ 7.546648] ata1.00: cmd 60/00:00:e0:4b:61/01:00:02:00:00/40 tag 0 ncq 131072 in
[ 7.546649] res 40/00:28:e0:4c:61/00:00:02:00:00/40 Emask 0x10 (ATA bus error)
[ 7.546794] ata1.00: status: { DRDY }
[ 7.546847] ata1.00: failed command: READ FPDMA QUEUED
[ 7.546906] ata1.00: cmd 60/00:08:90:2f:48/01:00:02:00:00/40 tag 1 ncq 131072 in
[ 7.546907] res 40/00:28:e0:4c:61/00:00:02:00:00/40 Emask 0x10 (ATA bus error)
[ 7.547053] ata1.00: status: { DRDY }
[ 7.547106] ata1.00: failed command: READ FPDMA QUEUED
[ 7.547165] ata1.00: cmd 60/00:10:90:30:48/01:00:02:00:00/40 tag 2 ncq 131072 in
[ 7.547166] res 40/00:28:e0:4c:61/00:00:02:00:00/40 Emask 0x10 (ATA bus error)
[ 7.547310] ata1.00: status: { DRDY }
[ 7.547363] ata1.00: failed command: READ FPDMA QUEUED
[ 7.547422] ata1.00: cmd 60/00:18:50:c7:64/01:00:02:00:00/40 tag 3 ncq 131072 in
[ 7.547423] res 40/00:28:e0:4c:61/00:00:02:00:00/40 Emask 0x10 (ATA bus error)
[ 7.547568] ata1.00: status: { DRDY }
[ 7.547621] ata1.00: failed command: READ FPDMA QUEUED
[ 7.547681] ata1.00: cmd 60/00:28:e0:4c:61/01:00:02:00:00/40 tag 5 ncq 131072 in
[ 7.547682] res 40/00:28:e0:4c:61/00:00:02:00:00/40 Emask 0x10 (ATA bus error)
[ 7.547825] ata1.00: status: { DRDY }
[ 7.547882] ata1: hard resetting link
[ 7.864408] ata1: SATA link up 6.0 Gbps (SStatus 133 SControl 300)
[ 7.886351] ata1.00: configured for UDMA/133
[ 7.886375] ata1: EH complete
[ 7.890012] ata1: limiting SATA link speed to 3.0 Gbps
[ 7.890016] ata1.00: exception Emask 0x10 SAct 0x7 SErr 0x280100 action 0x6 frozen
[ 7.890093] ata1.00: irq_stat 0x08000000, interface fatal error
[ 7.890152] ata1: SError: { UnrecovData 10B8B BadCRC }
[ 7.890210] ata1.00: failed command: READ FPDMA QUEUED
[ 7.890272] ata1.00: cmd 60/00:00:90:33:48/01:00:02:00:00/40 tag 0 ncq 131072 in
[ 7.890273] res 40/00:10:e0:4f:61/00:00:02:00:00/40 Emask 0x10 (ATA bus error)
[ 7.890418] ata1.00: status: { DRDY }
[ 7.890472] ata1.00: failed command: READ FPDMA QUEUED
[ 7.890530] ata1.00: cmd 60/00:08:90:34:48/01:00:02:00:00/40 tag 1 ncq 131072 in
[ 7.890531] res 40/00:10:e0:4f:61/00:00:02:00:00/40 Emask 0x10 (ATA bus error)
[ 7.890672] ata1.00: status: { DRDY }
[ 7.890724] ata1.00: failed command: READ FPDMA QUEUED
[ 7.890781] ata1.00: cmd 60/78:10:e0:4f:61/00:00:02:00:00/40 tag 2 ncq 61440 in
[ 7.890782] res 40/00:10:e0:4f:61/00:00:02:00:00/40 Emask 0x10 (ATA bus error)
[ 7.890925] ata1.00: status: { DRDY }
[ 7.890981] ata1: hard resetting link
[ 8.208021] ata1: SATA link up 3.0 Gbps (SStatus 123 SControl 320)
[ 8.230100] ata1.00: configured for UDMA/133
[ 8.230124] ata1: EH complete
SATAインターフェイスが6Gbpsリンクを使用しようとした後、惨めに失敗し、Linuxが3Gbpsにフォールバックしたようです。システムは毎回正常に起動し、高負荷で動作するため、これは私にとっては多少問題ありません(cd linux-3.2.8; make -j16
)。 memtest86 +も実行しましたが、エラーは見つかりませんでした。
私がもっと心配しているのは、Grubが画像をロードするのに長い時間がかかる場合や、完全にロードできない場合があることです。エラーは一貫しており、確率的です。つまり、起動するたびに失敗する可能性があります。
実は、失敗の原因には少し疑いがあります。ケーブルを見てください: どのようなエンジニアがこのようにしますか?いや。 1Gbpsイーサネットでさえ、小さな角度で曲がったケーブルをほとんど許容しません。そこには6GbpsSATAがあります。
エラーの原因を特定して修正したり、リンクを3Gbpsモードに永続的に切り替えたりする方法は?
1.5GbpsにフォールバックするVertex2で、まったく同じ問題が発生します。私は現在、アジアで手作りされたがらくた折りケーブルも疑っています(2本のワイヤーの間にはんだボールが見つかりました...幸い短絡はありませんでした)ケーブルを一時的に広げると問題が解決します。機械式ハードドライブに交換することでも問題は解決しますが、速度が大幅に低下し、EMCの影響を受けにくくなります。問題がケーブルまたはSSDにあることを確認するために、ラップトップVertex2をデスクトップVertex3と交換する必要があります。
編集:こんにちは皆さん、私はより多くのコンテキストを追加する必要があります。まず、私のVertex2は、以前はパニックロックされていたため、RMAからの新しいものでした。 (ちなみに、送料を15ユーロほど払わなければならないことに腹を立てていました。)最初の電源投入以来、ランダムに「ディスク障害を修正」しました。私は、最初のvertex2が10か月間正常に機能したことを正確に示しています。それで、それが再びOCZの問題であることを確認するために、私はそれをデスクトップコンピューターからvertex3と交換することに成功しました。残念ながら、vertex2またはケーブルを区別するような結果は得られません。確かに、ラップトップへのVertex3は魅力のように機能し、デスクトップへのVertex2はそれ以上クラッシュしません...明らかに、私は2日間、再起動、コールドスタート、ケーブルの移動を何十回も試みました...そしてVertex2をラップトップに戻すと、すべてのネジを締めた後、「ディスク障害を修正」しました。 :-)それで、私は古いハードディスクドライブを元に戻しました。低速ですが信頼性があります...新しいRMAを支払いたくないので、Vertex2をどうするかわかりません。これ以上購入することはありません。 OCZ。
コメントに答えるには:これはネットブックのSamsung NF310であるため、ODDをSSDと交換できないため、ODDはありません。