HP ProLiant Gen8サーバーが再起動時に、ルート(または/opt/hp/hp-snmp-agents/cma.conf
で構成された宛先)に電子メールで次のメッセージを報告することに気づきました。
Trap-ID=11020
cpqHoMibHealthStatusArray has changed to the value :02 03 02 02 02 02 02 03 02 02 02 02 02 01 01 02
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
または時々...
Trap-ID=11020
cpqHoMibHealthStatusArray has changed to the value :02 04 02 02 00 00 02 04 02 02 02 02 02 01 01 02
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
これはEL6.xとGen8の組み合わせに固有のようで、hp-snmp-agents
サービスの初回起動時または再起動時に発生します。この出力の意味について何か考えはありますか?
これは文書化されています。 HPブログの「 HP ProLiant Gen8エージェントレス管理の概要 」という投稿をチェックしてください。関連する部分を以下にコピーします。基本的に、各配列要素は、異なる監視対象コンポーネントのステータスです。
「cpqHoMibHealthStatusArray」の定義:
cpqHoMibHealthStatusArray OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..256))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The MIB Health Status Array is an array of status values representing an
overall status in element 0 follwed by server and storage status values as follows:
Octet Element Field
======== ======= =========
0 0 Aggregated Status of array elements
1 1 Status of element 1
2 2 Status of element 2
.
.
.
n n Status of element n
Status 0 - Not available
1 - Other
2 - OK
3 - Degraded
4 - Failed
.
.
Mibs are assigned an array element as follows. New items are added at the end.
0 - System Health Status (overall status as reported by who is reporting (agents or iLO))
1 - Total Aggregate (Includes IML Status)
2 - Processors (TBD 232.1.2.2.4:cpqSeCpuCondition)
3 - Memory (232.6.2.14.4:cpqHeResilientMemCondition)
4 - Cooling (232.6.2.6.4:cpqHeThermalSystemFanStatus)
5 - Sensors (232.6.2.6.3:cpqHeThermalTempStatus)
6 - Power (232.6.2.9.1:cpqHeFltTolPwrSupplyCondition)
7 - ProLiant Logs (232.6.2.11.2:cpqHeEventLogCondition)
8 - ASR (232.6.2.5.17:cpqHeAsrCondition)
9 - Drive Array (232.3.1.3:cpqDaMibCondition)
10 - SCSI (232.5.1.3:cpqScsiMibCondition)
11 - Storage Enclosures (232.8.1.3:cpqSsMibCondition)
12 - IDE (232.14.1.3:cpqIdeMibCondition)
13 - FC (232.16.1.3:cpqFcaMibCondition)
14 - Networks (232.18.1.3:cpqNicMibCondition)
15 - MP (232.9.1.3:cpqSm2MibCondition) "
HP SIM MIBキットのドキュメント に詳細があります。